These instructions help you get the best possible sound from your R35.

Phase

The phase of the AC supply can make a significant difference to the sound.

Use the Polarity Pen supplied with the R35 to verify which pin is live on your AC power cable.

Ensure that the live pin of the AC power cable is connected to the left-hand pin of the power connector, viewed from the back panel:

Burn-in

Your Primare will start to sound best after an initial burn-in of approximately 24 hours.

You will notice a further smaller improvement in sound quality for at least another 3 days’ playing.

Trigger

For convenience the R35 can be powered on and off via a remote link cable, avoiding the need to switch it on or off separately from the preamplifier in the system.

To power the R35 on and off remotely from a Primare processor or preamplifier connect the TRIG OUT signal from the processor/preamplifier to the TRIG IN socket on the R35, using a mono 3.5mm jack plug.

The TRIG OUT socket can be used to daisy-chain the trigger output signal to further Primare products.

Setting the impedance and capacitance

The default setting for the input impedance is 47kΩ (MM and MC settings), with a capacitance setting of 100pF (MC and MM settings). These settings should be adjusted using the DIP switches on the back panel according to the recommended settings for the cartridge installed.

  • Remove both plates by unscrewing the retaining thumb screws.

  • Set the switches up (OFF) or down (ON) according to the following tables.

You only need to set the switches appropriate to the type of cartridge you are using.

There are two sets of switches, one for the L channel and one for the R channel. Set the L and R switches to the same positions.

Choosing the correct settings

Details of the recommended settings will be provided in the documentation for the cartridge you are using. We suggest listening to values either side of the recommended ones to choose the ideal settings for your system.

MM impedance

Switch 8
47kΩ OFF
2.5kΩ ON

MM capacitance

Switch 9 10
100pF OFF OFF
200pF OFF ON
300pF ON OFF
400pF ON ON

MC impedance

Switch 1 2 3 4 5 6
10Ω ON ON ON ON ON ON
15Ω ON OFF ON ON OFF ON
18Ω OFF OFF ON OFF OFF ON
20Ω OFF OFF OFF OFF OFF ON
25Ω ON ON ON ON ON OFF
30Ω ON ON OFF ON ON OFF
40Ω ON OFF ON OFF ON OFF
50Ω OFF OFF OFF OFF ON OFF
60Ω ON ON ON ON OFF OFF
70Ω OFF OFF ON ON OFF OFF
80Ω ON ON OFF ON OFF OFF
90Ω ON OFF OFF ON OFF OFF
100Ω OFF OFF OFF ON OFF OFF
150Ω ON ON ON OFF OFF OFF
180Ω OFF ON ON OFF OFF OFF
200Ω ON OFF ON OFF OFF OFF
250Ω OFF OFF ON OFF OFF OFF
400Ω ON ON OFF OFF OFF OFF
600Ω OFF ON OFF OFF OFF OFF
1kΩ ON OFF OFF OFF OFF OFF
47kΩ OFF OFF OFF OFF OFF OFF

MC capacitance

Switch 7
100pF OFF
1nF ON

 


Printing or saving as PDF

You can print an on-line Primare user guide from your web browser, to provide you with a permanent copy to refer to away from your computer.

Alternatively, you can save a user guide as PDF files, to refer to when are you not connected to the internet.

To do so, simply choose Print, or Print followed by Save as PDF, from your browser’s File menu.

For the specific procedure for each of the most popular web browsers see How do I print or save a PDF copy of the on-user guides?.

Translate

You can use Google Translate to translate the contents of the Primare website. To do that, select the language you would like to translate into in the list below.

Please bear in mind, since the Google Translate is an automatically generated translation, we do not take any responsibility for errors in the text.